ST寫的STM8電機(jī)庫中,可以用無感方式驅(qū)動BLDC。STM8芯片只有一個(gè)AD轉(zhuǎn)換器,而且是8位機(jī)。庫中要對反
電勢采集,比較處理,還要進(jìn)行母線電壓,母線電流、散熱片溫度、電位器等模擬信號進(jìn)行采集、運(yùn)算和處理。
這優(yōu)先級處理說起來是很重要的。不過,ST把程序?qū)懙暮芎茫辽傥疫@樣認(rèn)為。它把不同的任務(wù)放到準(zhǔn)確的時(shí)間段里進(jìn)行采集處理。
先把它核心AD采集處理帖出來再分析 。
#ifdef SENSORLESS
@near @interrupt @svlreg void ADC2_IRQHandler (void)
{
if (ADC_State == ADC_SYNC)
{
// Syncronous sampling
u16 data;
u8 delay;
u16 bemf_threshold;
// Reset bit
bComHanderEnable = 0;
//clear interrupt flag
ADC2->CSR &= (u8)(~BIT7);
//left align - read DRH first
data = ADC2->DRH;
data <<= 2;
data |= (ADC2->DRL & 0x03);
switch( ADC_Sync_State )
{
case ADC_BEMF_INIT:
ADC2->CSR = (u8)((Current_BEMF_Channel|BIT5));
BEMF_Sample_Debounce = 0;
Zero_Sample_Count = 0;
ADC_Sync_State = ADC_BEMF_SAMPLE;
SetSamplingPoint_BEMF();
break;
case ADC_BEMF_SAMPLE:
//detect zero crossing
if( Current_BEMF == BEMF_FALLING )
{
if( Z_Detection_Type == Z_DETECT_PWM_OFF )
{
bemf_threshold = BEMF_FALLING_THRESHOLD;
}
else
{
bemf_threshold = hNeutralPoint;
}
if (Ramp_Step > FORCED_STATUP_STEPS)
{
if( data < bemf_threshold )
{
Zero_Sample_Count++;
BEMF_Sample_Debounce++;
if( BEMF_Sample_Debounce >= BEMF_SAMPLE_COUNT )
{
hTim3Th -= hTim3Cnt;
GetStepTime();
SpeedMeasurement();
bComHanderEnable = 1;
BEMF_Sample_Debounce = 0;
}
}
else
{
BEMF_Sample_Debounce = 0;
}
}
}
else
{
if( Z_Detection_Type == Z_DETECT_PWM_OFF )
{
bemf_threshold = BEMF_RISING_THRESHOLD;
}
else
{
bemf_threshold = hNeutralPoint;
}
if (Ramp_Step > FORCED_STATUP_STEPS)
{
if( data > bemf_threshold )
{
Zero_Sample_Count++;
BEMF_Sample_Debounce++;
if( BEMF_Sample_Debounce >= BEMF_SAMPLE_COUNT )
{
hTim3Th -= hTim3Cnt;
GetStepTime();
SpeedMeasurement();
bComHanderEnable = 1;
BEMF_Sample_Debounce = 0;
}
}
else
{
BEMF_Sample_Debounce = 0;
}
}
}
break;
case ADC_CURRENT_INIT:
ADC2->CSR = (ADC_CURRENT_CHANNEL|BIT5);
ADC_Sync_State = ADC_CURRENT_SAMPLE;
SetSamplingPoint_Current();
break;
default:
case ADC_AVCURRENT_INIT:
ADC2->CSR = (ADC_AVCURRENT_CHANNEL|BIT5);
ADC_Sync_State = ADC_AVCURRENT_CHANNEL;// ADC_USER_SYNC_SAMPLE;
SetSamplingPoint_AVCURRENT();
break;
case ADC_CURRENT_SAMPLE:
ADC_Buffer[ ADC_CURRENT_INDEX ] = data;
break;
case ADC_AVCURRENT_SAMPLE:
ADC_Buffer[ ADC_AVCURRENT_INDEX] = data;
break;
}
// Store the current channel selected
bCSR_Tmp = ADC2->CSR;
// Set the Async sampling channel
switch (ADC_Async_State)
{
default:
case ADC_BUS_INIT:
ADC2->CSR = (ADC_BUS_CHANNEL|BIT5);
ADC_Async_State = ADC_BUS_SAMPLE;
break;
case ADC_TEMP_INIT:
ADC2->CSR = (ADC_TEMP_CHANNEL|BIT5);
ADC_Async_State = ADC_TEMP_SAMPLE;
break;
case ADC_USER_ASYNC_INIT:
ADC2->CSR = (ADC_USER_ASYNC_CHANNEL|BIT5);
ADC_Async_State = ADC_USER_ASYNC_SAMPLE;
break;
}
// Disable ext. trigger
ADC2->CR2 &= (u8)(~BIT6);
//Start ADC sample
ADC2->CR1 |= BIT0;
ADC_State = ADC_ASYNC;
if (bComHanderEnable == 1)
{
ComHandler();
}
}
else
{
// Syncronous sampling
u16 data;
data = ADC2->DRH;
data <<= 2;
data |= (ADC2->DRL & 0x03);
//clear interrupt flag
ADC2->CSR &= (u8)(~BIT7);
// Restore the sync ADC channel
ADC2->CSR = bCSR_Tmp;
// Enable ext. trigger
ADC2->CR2 |= BIT6;
// Manage async sampling
switch (ADC_Async_State)
{
default:
case ADC_BUS_SAMPLE:
ADC_Buffer[ ADC_BUS_INDEX ] = data;
ADC_Async_State = ADC_TEMP_INIT;
break;
case ADC_TEMP_SAMPLE:
ADC_Buffer[ ADC_TEMP_INDEX ] = data;
ADC_Async_State = ADC_USER_ASYNC_INIT;
break;
case ADC_USER_ASYNC_SAMPLE:
ADC_Buffer[ ADC_USER_ASYNC_INDEX ] = data;
ADC_Async_State = ADC_BUS_INIT;
break;
}
ADC_State = ADC_SYNC;
}
}
#endif
上面的代碼我改了一點(diǎn)點(diǎn),就是多采集了一路平均電流。
AD采集分兩種,一個(gè)是同步,一個(gè)是異步。同步中有三個(gè)采集通道,異步中有三個(gè)采集通道。同步中的通道為反電勢通道、瞬時(shí)電流、平均電流。異步采集中通道為母線電壓、溫度值、電位器。
異步采集是在同步完成后進(jìn)行的。同步采集是通過TIM1的通道4觸發(fā)采集。
所以每個(gè)PWM周期采集2路模擬信號。異步采集的通道與PWM的ON與OFF狀態(tài)無關(guān),所以安排在異步采集中。同步采集中的反電勢需要在PWM固定 時(shí)刻采集,或ON或OFF,看BEMF的過零比較方案。瞬時(shí)電流一般在TON時(shí)刻采集。因?yàn)樵瓉鞸T有PWM特殊時(shí)刻做了一路用戶通道中,所以我就把平均 電流加到這一通道上了。其實(shí)平均電流采集也可以放到異步中。無所謂了,功能實(shí)現(xiàn)是沒問題的。
另外,異步采集中的反電勢通道一直是設(shè)為浮空相的通道的。而且反電勢的采集在D與Z之間,即退磁結(jié)束與過零點(diǎn)之間進(jìn)行的異步采集均為反電勢,而瞬時(shí) 電流的采集是在Z與C之間,即過零與換相之間進(jìn)行的異步采集均為瞬時(shí)瞬時(shí)電流。所以用戶的通道(平均電流)就是在換相與退磁之間了。
ST的無感方案,啟動方案感覺只能針對工業(yè)用電機(jī),像在4極對下4K轉(zhuǎn)速的電機(jī),那啟動參數(shù)不用怎么改。但如果改為航模電機(jī),無論啟動 PWM改為多少,總是不能啟動成功??赡苁俏疫€找到巧門,也可能沒設(shè)對參數(shù),對于高速電機(jī),像這種無感啟動可能是升頻升壓法啟動才可靠。我早期寫的例程, 無論什么電機(jī),用的是升頻升壓法,無論什么電機(jī),都可以正常啟動,只是啟動過程(大約1S)電流從大到小,,至少正常運(yùn)行至最小電流值。